Model No. : 1078/6
Brand Name : Brando
Function : Normally Closed
Name : 1078/6 Castel Type Refrigeration Solenoid Valve
Connection Size : 3/4'' ODF
Operation : Diaphragm Pilot Operated
Voltages : DC4V, AC110V, AC220V, AC230V
Refrigerants : CFC, HCFC, HFC
Medium Temperature : -35 To +105℃
Min. Operating Pressure : 0.05MPa
Max. Operating Pressure : 2.5MPa
Application : Commercial Refrigeration Systems And On Civil And Industrial Air Conditioning Plants
lagi
9yrs

Ningbo, Zhejiang, China

Kunjungi toko
  • Pemasok Emas
  • Sertifikasi Platform
  • Sertifikasi SGS
  • Ekspo online
  • Video

Deskripsi Produk

1078/6A6 3/4 '' Solder Air Conditioner HM2 Solenoid Valve


Yang ditampilkan di Chaptern ini adalah Castel Type 1078/6 3/4 '' 'ODF Solenoid Valves dengan koneksi pengelasan untuk pendingin, yang dirancang untuk pemasangan pada sistem pendingin komersial dan pada pabrik pengkondisian sipil dan industri yang menggunakan refrigeran berikut: R22, R134A, R404A, R407C, R410A; R507 di Grup II. Ketika kumparan diberi energi dengan kontrol dingin dengan setpoint, plunger membuka kursi katup yang menghubungkan saluran masuk ke outlet untuk memungkinkan aliran terbuka.

Fitur dan keuntungan:
1. Katup solenoid biasanya ditutup (NC) tanpa kumparan.
2. Tindakan langsung dan versi pilot diafragma tersedia.
3. Katup akting langsung beroperasi di medan magnet dan dapat dibuka dengan tekanan diferensial nol.


Dimensi keseluruhan 1078/6 3/4 '' ODF Diafragma ODF Castel Type Solenoid Valve:

1078/6 3/4'' ODF Diaphragm Operated Castel Type Solenoid Valve


Data Teknis 1078/6 3/4 '' ODF Katup solenoid tipe castel yang biasanya tertutup untuk pendinginan:

Model No.

SAE or ODF

Port Size

Operating Principles

KV

(m³/h)

MSV-1020/2 1/4'' SAE Direct Acting 0.175
MSV-1020/3 3/8'' SAE Direct Acting 0.23
MSV-1028/2 1/4''  ODF Direct Acting 0.15
MSV-1028/3 3/8'' ODF Direct Acting 0.23
MSV-1064/3 3/8'' SAE Diaphragm Pilot Operated 0.8
MSV-1064/4 1/2'' SAE Diaphragm Pilot Operated 0.8
MSV-1068/3 3/8'' ODF Diaphragm Pilot Operated 0.8
MSV-1068/4 1/2'' ODF Diaphragm Pilot Operated 0.8
MSV-1070/4 1/2'' SAE Diaphragm Pilot Operated 2.2
MSV-1070/5 5/8'' SAE Diaphragm Pilot Operated 2.61
MSV-1078/4 1/2'' ODF Diaphragm Pilot Operated 2.2
MSV-1078/5 5/8'' ODF Diaphragm Pilot Operated 2.61
MSV-1078/6 3/4'' ODF Diaphragm Pilot Operated -
MSV-1078/9 1 1/8'' ODF Diaphragm Pilot Operated 10
MSV-1078/11 1 3/8'' ODF Piston Pilot Operated 16
MSV-1090/5 5/8'' SAE Diaphragm Pilot Operated 3.8
MSV-1090/6 3/4'' SAE Diaphragm Pilot Operated 4.8
MSV-1079/7 7/8'' ODF Diaphragm Pilot Operated 2.61
MSV-1079/11 1 3/8'' ODF Diaphragm Pilot Operated 10
MSV-1079/13 1 5/8'' ODF Piston Pilot Operated 16
MSV-1098/7 7/8'' ODF Diaphragm Pilot Operated 5.7
MSV-1099/9 1 1/8'' ODF Diaphragm Pilot Operated 5.7
MSV1099/11 1 3/8'' ODF Piston Pilot Operated 10

Rincian Tampilan MSV1078/6 Diafragma Pilot yang Dioperasikan Katup Elektromagnetik:

MSV1078/6 Diaphragm Pilot Operated Electromagnetic Valve


Tampilan Kemasan Independen 1078/6 3/4 '' ODF Castel Type Solenoid Valve:

1078/6 3/4'' ODF Castel Type Solenoid Valve

Pemasangan katup solenoid seri msv tipe castel:
Semua katup dalam bab ini dapat dipasang pada tiga cabang utama tanaman (garis gas panas, garis cair, dan garis hisap), sambil menghormati batas penggunaan dan kapasitas, karakteristik fungsional berikut dari katup solenoid:
1. Dimensi Koneksi
2. PS: Tekanan maksimum yang diijinkan dari refrigeran
3. TS: suhu maksimum / minimum yang diijinkan dari refrigeran
4. TA: suhu sekitar maksimum / minimum yang diijinkan
5. KV: Faktor Pembuangan
6. Minopd: Diferensial tekanan pembukaan minimum. Ini adalah perbedaan tekanan minimum antara saluran masuk dan outlet di mana katup solenoid yang dioperasikan pilot dapat terbuka dan tetap dibuka atau ditutup dan mempertahankan segel.
7. MOPD: Diferensial tekanan pembukaan maksimum menurut AHRI Standard 760: 2014. Ini adalah perbedaan tekanan maksimum antara inlet dan outlet di mana katup solenoid dapat terbuka.


Sebelum menghubungkan katup ke pipa, disarankan untuk memastikan bahwa sistem pendingin bersih. Faktanya, katup dengan gasket PTFE, dan khususnya katup piston, sensitif terhadap kotoran dan puing -puing. Selain itu, periksa apakah arah aliran dalam pipa sesuai dengan panah yang dicap pada badan katup. Semua katup dapat dipasang di posisi apa pun selama koil tidak mengarah ke bawah. Brazing katup dengan koneksi solder harus dilakukan dengan hati -hati, menggunakan bahan pengisi titik leleh rendah. Tidak perlu membongkar katup sebelum membrazing, tetapi penting untuk menghindari kontak langsung antara nyala obor dan tubuh katup, yang dapat rusak dan kompromi fungsi katup yang tepat. Sebelum menghubungkan katup ke sistem listrik, pastikan bahwa tegangan dan frekuensi saluran sesuai dengan nilai yang ditandai pada koil.


Fokus pada tuntutan Anda, tawarkan solusi terbaik Anda:


√ hubungi kami jika beberapa poin Anda ragu

√ hubungi kami jika di suatu tempat perlu diubah
√ hubungi kami jika bukan yang Anda cari

√ hubungi kami jika Anda melakukan desain


Selamat datang di pertanyaan dan pertanyaan Anda!

Video

mengirimkan permintaan

Peringatan Produk

Berlangganan kata kunci yang Anda minati. Kami akan mengirimkan produk terbaru dan terpanas ke kotak masuk Anda. Jangan lewatkan informasi perdagangan apa pun.