XMT *908 Seri Kontrol Suhu Intellektif meter

Instruksi manual

Ⅰ 、 Spesifikasi Teknis Utama

L pengukuran penyimpangan: ≤ ± 0,5%f · s ± 1

L Kompensasi Kompensasi Akhir Dingin: ≤ ± 2.0 ℃

l Siklus Pengambilan Sampel: 0,5S

l Siklus kontrol: output relai 2 ~ 120S, lainnya adalah 2s.

l relai output kapasitas kontak: AC250V/7A (beban resistansi) atau AC250V/0.3A (beban persepsi)

l Mengemudi output pulsa yang dapat dikendalikan: ≥3V lingkup, ≥40us lebar lebih dari nol atau pemicu pulsa kontak

l Mengemudi output sinyal relai padat: Mengemudi arus listrik ≥15mA, tegangan ≥9v.

l PID kontinu: 0 ~ 10mA (beban 500 ± 200Ω), 4 ~ 20mA (beban 250 ± 100Ω),

atau 0 ~ 5V (beban ≥100kΩ), 1 ~ 5V (beban ≥100kΩ)

l Catu Daya: AC85V ~ 242V, 50/60Hz

L Kondisi Kerja: Suhu 0 ~ 50.0 ℃, Kelembaban Relatif ≤85%RH, Tanpa Korosi dan Radiasi Listrik yang Kuat.

Ⅱ 、 Kode Produk:

Xmt 9 8

(1) ⑵ (3) (4) (5)

(1) Dimensi Faceplate Meter

Blank: 160mm × 80mm x 120mm Instalasi Lubang: 152mm x 76mm

A: 96mm x 96mm x 110mm Instalasi Lubang: 92mm x 92mm

D: 72mm x 72mm x 110mm Lubang instalasi: 68mm x 68mm

E: 48mm x 96mm x 110mm Lubang Instalasi: 44mm x 92mm

F: 96mm x 48mm x 110mm Instalasi Lubang: 92mm x 44mm

S: 80mm x 160mm x 120mm Lubang Instalasi: 76mm x 156mm

G: 48mm x 48mm x 110mm Instalasi Lubang: 44mm x 44mm

(2) Desain nomor seri

(3) Alarm

“0”: tidak ada alarm “1or2”: satu alarm (batas atas, batas bawah) “5”: alarm suara

"3": dua alarm grup (batas atas, batas bawah, alarm penyimpangan positif dan pengaturan diskresi alarm deviasi negatif)

(4) Sinyal Input

"8": Pertukaran gratis dari sinyal input

⑸ Metode Kontrol

Blank: Kontak relay

"A": penyesuaian pemicu over-nol fase tunggal

"A3": Penyesuaian pemicu over-nol tiga fase

"B": Penyesuaian pemicu fase-fase-fase tunggal

"B3": Penyesuaian pemicu pemicu fase tiga fase

“C”: 0-10mA atau 4-20mA output arus listrik konstan

“G”: Solid State Relay (SSR) Output

Ⅲ 、 Instruksi Panel (Konsultasikan)

1

Ⅳ 、 mode pengaturan kode

Series

Code

Name

Setting range

Manual

Remarks

0

SP

Appointed data

Determined by P-SL P-SH

50.0

1

AL-1

Alarm 1

Determined by P-SL,P-SH when the upper and lower limit range,it is050.0 when the upper and lower limit deviation alarm

Alarm 1 setting value

10

2

AL-2

Alarm 2

Determined by P-SL,P-SH when the upper and lower limit range,it is050.0 when the upper and lower limit deviation alarm

Alarm 1 setting value

10

3

P

Proportion modulus

0100

When the P↑,the the proportion function

When P=0,the meter is ON/OFF control

8

4

I

Calculus time

02000S

240

5

d

differential time

0200S

30

6

At

Setting itself

ON:open setting inself function

OFF:close setting itself function

Select of setting itself

OFF

7

t

SSR proportion Control period

1120S

the movements cycle ON/OFF of Setting relays control is no meaning

20

8

Hy

Main control by

drop in level

0.150.0

Only have meaning when main control output is ON/OFF(P=0)

1.0

9

Hy-1

Alarm 1

drop in level

0.150.0

It has use drop in level setting of alarm contact output

1.0

10

Hy-2

Alarm 2

drop in level

0.150.0

It has use dropin level setting of alarm contact output

1.0

11

Pb

Sensor error amendment

±20.0

The sensor have deviation can use item to revisal

0

12

FILT

Filt modulus

050

Is the software filter constants of  measurement sampling.The constant ,the Measurements antijamming capabilityMeasurements antijamming capability↑,but the measurement and system time

20

13

dp

Show accuracy

01

0: have radix point,1: have no radix point

14

P-SH

Display the high limit

P-SL9999

Can set the high limit displaying input signal

400

15

P-SL

Display the low limit

-1999P-SH

Can set the low limit displaying input signal

0

16

OUTL

Allow exports  min value

0OUTH

It will no role when highest outputlimit,,manual and position.

200.0

17

OUTH

Allow exports  max value

OUTL200

It will no role when lowest outputlimit,,manual and position.

0.0

18

ALP1

Alarm1  and output definition

04

‘0’:indicate no alarm

‘1’:upper limit touch alarm

‘2’:lower limit touch alarm

‘3’:upper windage alarm

‘4’:lower windage alarm

19

ALP2

Alarm2  and output definition

04

20

COOL

System function choice

01

‘0’:reverse control

‘1’:positive control

0

21

OPPO

Open power output

0100

Soft start functionthat meters coefficient after first export of electric power

0

22

LOCK

Code lock

050

0- all the parameter can be revised

1- only the sp can be revised

0

23

Sn

Input type

070.

0-CU50 (-50.0150.0) ;1-PT1 (-200.0200.0) ;2-PT2 (-200.0600.0) ;3-K (01300) ;4-E (0700.0) ;5-J (0900.0) ;6-T (-200400.0) ;7-S (01600) ;

24

OP-A

Output type

14

1- RLP SSR output mode

2- SSR solid state relay

3- Zero controllable silicon contact signal when it exceed zero output mode

4- Mut controllable silicon phase trigger contact output mode

5- 0~10MA linearity  control electric current output

6- 4~20MA  linearity  control electric current output


Ⅴ 、 indeks teknis

1 、 Area pengaturan pertama

Tekan tombol Set 3S masuk ke area pengaturan pertama, meter akan menampilkan kode parameter 1 ~ 24 di jendela di baris atas dan menampilkan data parameter di baris rendah. Pada saat ini tekan tombol ▲ 、 ▼ atau T untuk menyesuaikan parameter, lalu tekan tombol Set untuk melestarikan. Tekan tombol Set lama akan menarik atau tekan tombol + ƒ akan langsung menarik. Jika dalam 10 detik tidak menekan setiap tombol maka secara otomatis akan melestarikan data dan menarik pengaturan.

2 、 Area pengaturan kedua

Ketika meter diatur dengan listrik, tekan tombol set masuk ke area pengaturan kedua, Anda dapat sesuai 1 untuk mengatur "SP".

3 、 Peraturan Manual

Ketika meter diatur dengan listrik, tekan tombol T sekitar 3s masuk ke dalam regulasi manual, itu akan menampilkan "h" di baris bawah, pada saat ini dapat mengatur daya output; Tekan tombol T sekitar 3s lagi itu akan menarik peraturan manual.

Ⅵ 、 pengaturan itu sendiri

Penggunaan meter pada pertama kalinya atau sekitarnya memiliki pengubah, menemukan itu mengendalikan tidak baik, saat ini Anda perlu menggunakan pengaturan itu sendiri. Misalnya:

Set pertama AT = ON, AM Light berkedip, meter masuk ke pengaturan itu sendiri, tekan tombol Set Enter ke dalam pengaturan parameter. Atur HY adalah 0,5 ~ 1 ℃, jika output adalah Relai mengatur t = 2s, meter memiliki tiga kali bergetar, parameter P, I, D yang diawetkan secara otomatis, dan AT Light Off, pengaturan itu sendiri selesai.

Ⅶ 、 Skema Koneksi (Konsultasikan)

2

★ Komentar : Perusahaan kami akan meningkatkan teknologi produk 、 Desain dan spesifikasi , ini dikonfirmasi ke objek .。


  • Sebelumnya: XMT-808 Series Universal Input Jenis Pengontrol Suhu Cerdas
  • Berikutnya: FC-040 Tipe Input Tunggal Pengontrol Suhu Cerdas

  • mengirimkan permintaan

    Peringatan Produk

    Berlangganan kata kunci yang Anda minati. Kami akan mengirimkan produk terbaru dan terpanas ke kotak masuk Anda. Jangan lewatkan informasi perdagangan apa pun.